2 resultados para Positioning

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To evaluate the influence of implant positioning into extraction sockets on osseointegration. Material and methods Implants were installed immediately into extraction sockets in the mandibles of six Labrador dogs. In the control sites, the implants were positioned in the center of the alveolus, while in the test sites, the implants were positioned 0.8 mm deeper and more lingually. After 4 months of healing, the resorptive patterns of the alveolar crest were evaluated histomorphometrically. Results All implants were integrated in mineralized bone, mainly composed of mature lamellar bone. The alveolar crest underwent resorption at the control as well as at the test sites. After 4 months of healing, at the buccal aspects of the control and test sites, the location of the implant rough/smooth limit to the alveolar crest was 2 +/- 0.9 mm and 0.6 +/- 0.9 mm, respectively (P < 0.05). At the lingual aspect, the bony crest was located 0.4 mm apically and 0.2 mm coronally to the implant rough/smooth limit at the control and test sites, respectively (NS). Conclusions From a clinical point of view, implants installed into extraction sockets should be positioned approximately 1 mm deeper than the level of the buccal alveolar crest and in a lingual position in relation to the center of the alveolus in order to reduce or eliminate the exposure above the alveolar crest of the endosseous (rough) portion of the implant. To cite this article:Caneva M, Salata LA, de Souza SS, Baffone G, Lang NP, Botticelli D. Influence of implant positioning in extraction sockets on osseointegration: histomorphometric analyses in dogs.Clin. Oral Impl. Res. 21, 2010; 43-49.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a new mechanical samples positioning system that allows the safe placement and removal of biological samples for prolonged irradiation, in a nuclear reactor during full-power continuous operation. Also presented herein the materials of construction and operating principles. Additionally, this sample positioning system is compared with an existing pneumatic and automated transfer system, already available at the research reactors. The system consists of a mechanical arm with a claw, which can deliver the samples for irradiations without reactor shutdown. It was installed in the lEA-R1 research reactor at Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, Brazil, and for the past 5 years, the system has successfully operated and allowed the conducting of important experiments. As a result of its introduction, the facility has been in a position to positively respond to the increased demand in studies of biology, medicine, physics, engineering, detector/dosimeter calibrations, etc. It is one example of the appropriated technologies that save energy and resources. (C) 2010 Elsevier Ltd. All rights reserved.